Solar Fence Charger Not Working

Electric fence transformed exactly how we graze livestock in the Midwest. Now we have the right to inexpensively cordon off pastures to suit our changing forage needs. It can increase our productivity, and also all for the minor labor of relocating a few strings of wire or tape. But via all that relocating occasionally comes a little trouble. Shorts foil us. And, an electric fence via no electrical power equals cows on the run. So store your fencing toolbox up to date through a couple of handy fence-trial and error tools.

You watching: Solar fence charger not working

Tbelow are a number of different tools or techniques to check out if your electrical fence is functioning.

*
Popular favorites are the Fault Finder, Smart Fix and also Fence Compass devices. If you develop much electric fence, this tool is as handy as a pair of pliers. This tool tells you a number of things at a glance. It tells you if the fence has a brief as well as the output voltage of the fence. If the fence is shorted out, it likewise tells how a lot of a short it is by the amperage and also which direction the present circulation is. The higher number of amps the bigger the short. For example, if your fence voltage is 6 to 7 KV via 5 amp draw and also you formerly tested the fencer at a clean-fence reading of 9 KV and 0 amp attract, your project is done. This should be enough to turn cows away from the fence. But, if your voltage analysis is less than 50 percent of normal and the amp analysis is 10+, it is time to discover and fix some troubles. The amp readings on these testers are cumulative so tbelow can be multiple shorts.

Scenario #1Let’s assume, you are checking a fence via the tester and also there is no voltage analysis. Your initially speak is the charger/energizer. Test it and troubleshoot it. If it is on and clicking, revolve the charger off and also disattach the fence lead line. Turn the charger on and test it for voltage. If tright here is high voltage (very same as as soon as purchased), the problem is with the fence. In this situation, it might be a damaged wire, a poor splice joint, or anything that is not enabling voltage via. If the charger is clicking and tbelow is low voltage, or if it transforms on and won’t click, tbelow is a difficulty with the charger. Take it to your regional MFA for service.

Scenario #2Livestock is going through the electric fence when tright here is adequate voltage.This happens once the pet is not acquiring grounded and also not feeling the “shock.” Add more ground rods or install a hot-ground mechanism. Properly checking the ground mechanism is basic and must be done ybeforehand. You will need a digital volt meter or a fault finder via a ground probe and integrated digital volt meter to perform this.

Correctly install fencer and also rotate fencer on.

See more: Advanced Radiant Systems Inc, Advanced Radiant Systems, Inc

Go 100 yards ameans from the fencer and brief the fence voltage down to 1,000 volts. This have the right to be done by placing t-short articles or anything metal on the warm wires and also shorting out your fence.

With a digital volt meter, location the ground probe around 3 feet from the ground rods, and examine their voltage reading. Ideally you desire this analysis to be much less than 300 volts. You need to add even more ground rods if it procedures greater than 300 volts.

Think of the ground device as a huge antenna collecting all the positive electrons the short has funneled from the fence and also dumping them in the soil.

This is a measurement of “stray voltage” that is not being caught by the ground rods. If it is substantial, a far better ground is in order.Another way to resolve this difficulty is to make a hot/ground fence. This is done by alternating wires on multi-wire fence from the hot or positive side of fencer and also grounding the oppowebsite wires. This fence takes ground problem variables out of the equation. Electron circulation with the ground is sreduced when the soil is dry or frozen.

Knowing your fence mechanism and also devices before there is a trouble will makes troubleshooting much much easier when tbelow is a trouble.